| Classification | Tachometer | Model | H7CX-R11[]-N | H7CX-R11W[]-N | Input mode | 1 input only | 2 inputs only | Ratings | Power supply | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 12 to 24 VDC or 24 VAC, 50/60 Hz | Operating voltage | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| fluctuation range | 85% to 110% of rated supply voltage (90% to 110% at 12 to 24 VDC) | Power | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
consumption |
Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx. 3.7 W at | 12 to 24 VDC | Mounting method | Flush mounting or surface mounting | External connections | 11-pin socket | Degree of protection | IEC IP66, UL508 Type 4 (indoors) for panel surface only and when Y92S-29 Waterproof Packing is used | Input signals | Count and hold | Count 1 and count 2 | Pulse measurement method | Tachometer mode | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| (cycle measurement) | Maximum counting speed | 30 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| (minimum pulse | (minimum pulse |
width: 16.7 ms) or 5 kHz (minimum pulse width: 0.1 ms) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| (selectable) | Minimum input signal width | — | 10 ms | 1 ms | — | Measuring ranges | 0.001 Hz to 30.00Hz | 0.001 Hz to 10 kHz | 0.026 to 999999 s | 0.003 to 999999 s | 0.01 to 5k Hz | Sampling cycle | 200 ms min. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Continuous measurement | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Averaging not used: 200 ms Averaging used: 200 multiplied by the averaging setting (ms) Input pulse of less than 5 Hz Averaging not used: Two times the maximum input pulse cycle Using averaging: Two times the maximum of the input pulse cycle multiplied by the averaging setting. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| (at 23 ±5°C) | Output mode | HI-LO, AREA, HI-HI, LO-LO | HI-HI, LO-LO | Auto-zero time | 0.1 to 999.9 s (in Tachometer Mode) | Startup time | 0.0 to 99.9 s | Averaging | Simple averaging/moving averaging selectable, Number of times: OFF, 2, 4, or 8 times | Prescaling function | 0.001 to 99.999 (in Tachometer Mode) | Decimal point adjustment | Rightmost 3 digits | — | Sensor waiting time | 290 ms max. | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| (Control output is turned OFF and no input is accepted during sensor waiting time.) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
No-voltage Input Impedance when ON: 1 kΩ max. (Leakage current: 12 mA when 0 Ω) ON residual voltage: 3 V max. Impedance when OFF: 100 kΩ min. Voltage Input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 4.7 kΩ) | Hold input | Minimum input signal width: 20 ms | — | External power supply | 12 VDC (±10%), 100 mA | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| * Refer to Safety Precautions (Common) on Data Sheet for details. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Minimum applied load:10 mA at 5 VDC (failure level: P, reference value) | Display *2 | 7-segment, negative transmissive LCD | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Character height | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Present value: 10 mm (red), comparison value: 6 mm (green) | Digits | 6 digits (0 to 999999) | Memory backup | EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Operating temperature |
range | -10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation) | Storage temperature range | -25 to 70°C (with no icing or condensation) | Operating humidity range | 25% to 85% | Case color | Black (N1.5) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||